ETC-600 |
| |
|
| |
| SPECIFICATIONS |
- Small size, double sensor, with complete functions, suitable
for all kinds of refrigerated storage which needs complex measuring
and controlling of temperature
- Defrosting type options: electric-heat or thermal
- Switch between modes of refrigerating and heating
- Fan control: start/stop simultaneously with the compressor or
continuous running
- Defrost controlled by time and temperature
- Power supply 110/220VAC ± 10%, 50~60HZ
- Resolution 0.1°C
- Realy contact capacity 10A/240VAC
- Ambient temperature 60°C
- Relative humidity 10%~95% (no condensate)
- Hole size 70.5x28.5 mm
- Measuring range -40°C ~ 110°C
- Accuracy ± 0.5°C (-10°C~85°C)
- Other range: <± 2°C
- Product size 75x34x85 mm
- Sensor USA DALLAS
|
| |
| Code |
Meaning |
Range |
Unit |
Defaul |
| F01 |
Set temp. upper limit |
-39~+110 |
°C |
-15 |
| F02 |
Set temp. lower limit |
-40~109°C |
°C |
-20 |
| F03 |
Set alarming values when exceeding the
temp. limits |
0~20 |
°C |
10 |
| F04 |
Fast refrigeration time |
0~20 |
Hour |
4 |
F05
| Compressor start delayed |
0~20 |
Minute |
3 |
F06 |
Defrosting interval (cycle) |
0~99 |
Hour |
6 |
F07 |
Defrosting time |
0~99 |
Minute |
30 |
F08 |
Temperature when the defrosting process
ends |
-40~+50 |
°C |
10 |
F09 |
Temperature when the fan stops working |
-40~+50 |
°C |
2 |
|
| |
| |
| |
|
|
 |